BAOSTEEL METAL / MOTOR LAMINATION MATERIAL

50W470 Non-Oriented
Electrical Steel Coil

0.50 MM NOMINAL | NON-ORIENTED SILICON STEEL | P1.5/50 TESTING

MOTOR CORE LAMINATIONSMAGNETIC TEST REPORTSLITTING & COIL SUPPLY

ELECTRICAL STEEL / MOTOR OEM PROCUREMENT

Match magnetic performance to your lamination drawings and production line.

Source 50W470 non-oriented electrical steel coil for stamped motor cores, compressor motors and electromagnetic laminations. Specify 0.50 mm nominal gauge, certified P1.5/50 loss class, B50/J5000, insulation type and slit-coil size for a project-specific bulk quotation.

Check material and coil specifications ↓
50W470 non-oriented electrical steel coil for motor stator and rotor lamination production
8 Million MTAnnual production across the overall steel business
1 Million MTRegular inventory across the company steel business
500,000 m²Factory area
1,000+Employees across the business
MATERIAL IDENTIFICATION / 0.50 MM / MILL DATA

50W470 Electrical Steel Coil Specifications

Select 50W470 by a confirmed 0.50 mm gauge, 4.70 W/kg loss class, induction requirement, coating, and lamination-production dimensions.

Specification50W470 ordering guide
Commercial product name50W470 Non-Oriented Electrical Steel Coil
Material categoryCold-rolled, grain non-oriented electrical steel for laminated magnetic cores
Nominal base thickness0.50 mm nominal steel thickness; confirm tolerance and whether any coating-inclusive thickness is being specified
Grade / material certificate50W470 non-oriented electrical steel, with confirmed source-mill designation and an agreed grade specification; verify the exact certificate designation
Domestic reference specificationGB/T 2521.1-2016 (current) covers fully processed non-oriented electrical steel; agree its applicable grade schedule or a specific source-mill specification
International referenceIEC 60404-8-4:2022 + Amendment 1:2026 covers fully processed non-oriented electrical strip; any international grade substitution requires documented comparison
Magnetic measurementsSpecific total loss P1.5/50, induction / polarization B50 or J5000, and optional higher-frequency data
Illustrative loss request50W470 naming indicates the 4.70 W/kg class at 1.5 T / 50 Hz. Specify a contractual P1.5/50 limit of ≤4.70 W/kg and confirm it on the supplying mill MTC.
WidthDefine parent-coil or slit-strip width, tolerance and edge condition in the RFQ
Coil inside diameter508 / 610 mm commonly requested; confirm mill and slitting capability
Coil net massSpecify permissible minimum and maximum per coil and total net MT
Surface conditionFully processed / final annealed, with agreed insulating coating
Packaging and traceabilityProtected coil edges, corrosion/moisture packaging, coil identification and requested test documents
REQUEST A MILL-CONFIRMED OFFER

Put the magnetic acceptance criteria on your RFQ.

For electric-motor laminations, request a mill-issued certificate covering P1.5/50 and B50 along with coil geometry and insulation. Reference data for the B50A470 loss class is useful for preselection, not an automatic certificate for every 50W470 batch.

  • 50W470 designation and source mill / grade sheet
  • 0.50 mm nominal gauge, width, coil ID and mass
  • P1.5/50 target and required B50/J5000 results
  • Insulation chemistry, coating mass or resistance if needed
  • Slit edge, burr target and punching die details
  • MTC, test method, packing and destination

All dimensional examples are RFQ fields, rather than a promise of available stock.

ELECTRICAL PERFORMANCE / LOSS / INDUCTION

Magnetic Properties & Iron Loss Acceptance

Electrical steel is selected by certified magnetic loss, induction and coating properties. For a 0.50 mm loss-class material, compare both magnetic specifications and stamping-line constraints.

Magnetic or process itemReference / conditionHow to confirm
Nominal gauge0.50 mm0.50 mm, measured to contracted thickness tolerance; check steel-only versus coated-gauge basis
Specific total lossP1.5/50 at 1.5 T, 50 HzP1.5/50 ≤4.70 W/kg is the 50W470 loss-class target; specify the applicable test method, source-mill guarantee and lot certificate
Magnetic induction / polarizationB50 / J5000 at 5,000 A/mB50 / J5000 measured at 5,000 A/m. Published B50A470 reference: B50 ≥1.64 T; confirm actual 50W470 mill grade limits before substitution.
60 Hz / higher-frequency lossP at the specified frequency and polarizationSpecify tests where motor operation or project standard requires them.
Lamination / stacking factorMill-reported value at agreed coating conditionPublished B50A470 reference: stacking factor ≥96%; coating and actual supplied grade may change the acceptance value
Surface insulation resistanceCoating-specific test method and acceptanceAgree coating type, resistance, mechanical compatibility and test requirement.
Burr / cut-edge qualitySlitting and stamping specificationAgree inspection location, allowable burr and edge protection.
0.50 mmNominal sheet thickness associated with the “35” designation
1.5 TReference magnetic polarization / induction used for the stated loss index
50 HzFrequency of P1.5/50 loss testing
Mill MTCActual acceptance basis for certified magnetic and coating performance
Grade identification note: 50W470 is offered under a commercial designation. Published general-grade tables do not establish a universal 50W470 guarantee in every GB or IEC edition. The 4.70 W/kg figure is an RFQ acceptance target only where specifically certified by the supplying mill. Avoid substituting a 50W470 (0.50 mm) certificate for 50W470 (0.50 mm).
BUYER SELECTION / VERIFY BEFORE ORDER

How to Specify 50W470 for Your Motor Project

Use 50W470 for cost/performance screening only after its loss, induction, surface insulation and blanking specifications match the approved motor-core design.

01 / GRADE ID

Confirm the supplying mill

Request the supplying mill’s 50W470 datasheet, 0.50 mm thickness tolerance, fully processed delivery state and the actual GB/mill grade designation.

02 / LOSS BASIS

Set the exact test conditions

Quote P1.5/50 ≤4.70 W/kg as a contractual target at 1.5 T and 50 Hz, with optional higher-frequency loss testing for inverter-fed machines.

03 / INDUCTION

Review B50 or J5000

Use B50/J5000 at 5,000 A/m to compare candidate mills. B50A470 literature lists a 1.64 T minimum; confirm the actual 50W470 batch guarantee.

04 / COATING

Specify lamination insulation

Agree insulating-coating category, suitable punching performance, insulation-resistance target and stacking factor.

05 / COIL FORMAT

Match the stamping line

Include finished slit width, edge burr, coil inside diameter, individual coil mass and winding orientation.

06 / TRACEABILITY

Request certificate and samples

Identify test reports, batch identification, trial material and the acceptance procedure before production release.

Building a motor-core RFQ?

Send the drawing and required electromagnetic limits with coil width and tonnage.

ELECTRICAL INSULATION / COATING PERFORMANCE

Choose the Surface Insulation Your Core Assembly Needs

Coating performance affects interlaminar current flow, punchability and consistency when multiple stamped laminations are stacked.

COATED ELECTRICAL STRIP

Coating insulation protects the lamination stack.

Electrical steel is typically supplied with an insulating surface layer selected for the customer's stamping process and core assembly method. Confirm coating chemistry, coating mass and relevant surface-insulation resistance before placing the order.

ASTM A976 groups insulating coatings by composition and use; individual surface-resistance acceptance is a separate contractual requirement. Coating suitability depends on stamping, welding, bonding, temperature exposure and stress-relief practice.

  • Insulation-coating grade or mill code
  • Interlaminar resistance or Franklin-test requirement
  • Coating thickness and stacking factor
  • Punchability, edge burr and any post-punch processing
  • Core assembly route: riveting, welding, bonding or interlocking
0.50 mm non-oriented electrical steel insulated strip surface detail

Coil surface & coating quality

Use actual mill photos to show coating uniformity and coil edges; product performance depends on testing, not appearance alone.

STRIP DIMENSIONS / SLITTING / CORE BUILD

50W470 Strip Geometry & Lamination Control

For 0.50 mm coil, balance punching productivity, stacking factor, strip flatness and coating integrity against the motor-core drawing and annual consumption.

Slit non-oriented electrical steel coils prepared for precise lamination punching

Width & slit edge

Specify required slit width, width tolerance, coil set, edge burr target and compatibility with feeder equipment.

Motor stator and rotor stamped laminations made from non-oriented electrical steel

Lamination stacking

Confirm stacking factor, coating thickness, punched-part geometry and assembly method before large-batch production.

THICKNESS CONTROL

Measure nominal gauge and coating

Verify whether the requested 0.50 mm refers to steel substrate or coated overall thickness and cite the tolerance basis.

SLIT-COIL DIMENSIONS

Specify winding and handling

Provide strip width, coil ID, allowable coil mass, edge shape and required winding direction.

CORE ASSEMBLY

Plan lamination geometry

Check how coating, burr, stamping clearance and interlocking details affect the completed magnetic core.

FROM COIL TO MOTOR CORE

Processing Requirements for Stator and Rotor Laminations

Set slit width, burr, tool-feed pitch and sample-stamping acceptance before approving large-volume 0.50 mm laminations.

STEP 01

Drawing & sample

Share the stator/rotor drawing, gauge, blank dimensions and target motor performance.

STEP 02

Coil slitting

Select master coil width or slit strips with dimensional and edge acceptance.

STEP 03

Punching & stacking

Run customer tool trials and review burr, coating and stack height.

STEP 04

Magnetic validation

Confirm tested loss and induction from the agreed material lot; validate finished-core losses separately.

Performance at system level: Epstein strip measurements support material comparison, while finished motor-core loss is also affected by punching strain, joints, stacking, harmonics and assembly. Confirm motor efficiency against your own test program.
MOTOR CORES / ELECTROMAGNETIC COMPONENTS

Where 50W470 Electrical Steel Coil Is Used

50W470 is frequently evaluated for 50 Hz rotating machinery and laminated components. Check actual motor efficiency, frequency spectrum and the supplier’s magnetic test data.

Industrial motor stator core laminations produced from electrical steel strip
APPLICATIONS / ROTATING MACHINERY

Supply electrical steel for rotating magnetic circuits.

At 0.50 mm nominal gauge, non-oriented electrical steel is a practical material class for many general-purpose rotating-machine cores. Select an approved lot by iron loss, magnetic induction, coating and stamping characteristics.

  • Industrial motor stators and rotors
  • Fan and pump motor magnetic cores
  • Compressor and appliance motor cores
  • Small generators and other rotating machines
  • Selected magnetic components subject to design approval
INDUSTRIAL MOTORS

Stator lamination material

Validate the required P1.5/50 limit, B50 result, 0.50 mm stacking geometry and the completed motor’s efficiency targets.

HOME & COMMERCIAL

Compressor and fan motors

Confirm production stamping width, coating choice and consistency across deliveries.

ELECTROMAGNETIC DEVICES

Laminated magnetic parts

Evaluate the applicable flux-density range and frequency before finalizing material selection.

RFQ SUPPORT / COIL YIELD

Steel Coil Weight, Length & Blank Feed Calculator

Estimate 0.50 mm electrical steel coil length, strip mass per meter and theoretical blank-feed strokes before buying material for a motor-lamination line.

Electrical Coil Length Estimator

Enter the net steel coil mass and actual or agreed material density. Results exclude cores, packaging, winding gaps and slitting scrap.

Calculator default density is 7.70 g/cm³, a published reference for the B50A470 loss class; use the offered mill’s actual density and steel-thickness basis for purchase estimates. Blank strokes assume zero scrap and continuous usable length.

THEORETICAL ESTIMATE

Per-Coil Yield

Unwound strip length per coil—
——
Potential blank-feed strokes per coil (before scrap)—
—

This tool estimates steel-strip geometry and does not calculate core loss, actual core output or final stacked-core mass.

ELECTRICAL STEEL / PROCESS CONTROL

How Electrical Steel Coil Is Manufactured & Prepared

Electrical steel requires dedicated magnetic testing and insulating surface control in addition to dimensional checks.

PRODUCTION ROUTE / BATCH CONSISTENCY

From cold-rolled electrical strip to finished coils.

For 50W470-class fully processed non-oriented steel, the typical route includes rolling, final annealing, insulation coating and protected coiling. Confirm the final source mill’s production state, magnetic test basis and handling requirements in the order.

  • Mill-grade identity and selected magnetic loss classification
  • Nominal gauge control and surface quality
  • Full-processing / annealing condition
  • Electrical insulation coating and coil handling
  • Final magnetic testing and coil-to-batch traceability
Manufacturing Overview →
Cold rolled electrical steel coil manufacturing and processing equipment
WHY BAOSTEEL METAL

Bulk Electrical Steel Coil Procurement Support

Define the full 0.50 mm magnetic specification and order quantities in a single RFQ. Company scale figures apply to the overall steel business, not to verified 50W470 inventory.

COMPANY SCALE

Manufacturing network & supply

Company-wide steel manufacturing and inventory capacity supports sourcing across multiple flat-steel families. Exact 50W470 supply is confirmed separately.

TECHNICAL RFQ

Procurement by specification

Your inquiry can include induction values, core-loss limits, insulation specifications, tolerances and punch-trial documents.

INSPECTION

Traceable mill documentation

Request the designated mill grade sheet, magnetic test results, batch identification and inspection documents when quoting.

EXPORT

Coil packaging and logistics

Coordinate coil protection, individual coil limits, shipment labeling and destination requirements before release.

Need one qualified source for a repeat motor program?

Send the mill grade, sample acceptance criteria and planned order volume.

COIL INSPECTION / TEST CONDITIONS

Magnetic Testing & Quality Documentation

For a 50W470-class procurement, the MTC should link each coil/lot to the agreed P1.5/50 loss limit, B50/J5000 result, coating specification and thickness tolerance.

Electrical steel magnetic properties testing and inspection instruments
MAGNETIC TESTING / DOCUMENT CONTROL

Inspect properties that affect core performance.

Request an inspection plan covering the agreed steel grade, nominal thickness, iron loss, induction and coating. Depending on contract requirements, testing may include an Epstein-frame method and insulating-coating resistance checks.

  • Supplying mill specification and certified grade identification
  • Iron loss under agreed polarization and frequency conditions
  • B50 / J5000 magnetic test results when specified
  • Thickness, width, flatness, slit edge and burr condition
  • Insulation coating, adhesion and resistance when specified
  • Coil number, batch traceability and MTC supplied by agreement
Quality Control →
SLITTING / SAMPLE CUTTING / TOLERANCES

Optional Electrical Steel Processing for Your Line

Choose the processing scope after the mill grade and insulation coating have been approved.

01 / SLITTING

Slit coil for feeder requirements

Quote slit width, knife clearance constraints, edge burr, surface protection and acceptable width tolerance.

02 / CUT TO LENGTH

Trial sheets and blanks

Request sheet lengths or sample blanks for die validation if available for your chosen steel and coating.

03 / PACK IDENTIFICATION

Control traceability after processing

Maintain identification of the supplied parent coil, processed strip width and original material test documentation.

04 / MOTOR-CORE PROJECT

Align downstream punching

Send stamping drawings and blank-feed pitch; tooling validation remains part of the customer’s production process.

Processing availability: Slitting, cut-to-length and sampling are subject to order quantity, coating compatibility, facility capability and price confirmation.
SOURCING / INVENTORY CONFIRMATION

50W470 Coil Availability & Supply Planning

Company-wide inventory scale does not establish live stock for a specific electrical-steel magnetic grade.

AVAILABLE MATERIAL / ORDER PLANNING

Confirm coil weight, grade identity and lead time.

Inventory and lead time change by source mill, coating, width and quality acceptance. Share the complete material specification to verify a supply route for single orders and recurring deliveries.

  • Requested mill grade and certified loss / induction limits
  • 0.50 mm base thickness and strip width
  • Coating choice and process condition
  • Individual coil mass and batch/heat identification
  • Trial sample requirement and required dispatch window
Steel Inventory →
Protected electrical steel coils stored with batch identification labels
PROTECT COATING / PREPARE SHIPMENT

Export Packing for Electrical Steel Coil

Coordinate packing and identification with the quality documentation required by your receiving factory.

Electrical steel coils wrapped for export shipment and edge protection
COIL PACKING / MOISTURE CONTROL

Protect insulating coatings and slit edges in transit.

Electrical steel surface damage and moisture exposure can complicate downstream lamination manufacturing. Confirm wrapping, handling arrangement and coil labels before international dispatch.

  • Moisture-resistant wrapping and transport protection
  • Inner and outer edge guards for slit coils
  • Straps, pallets or cradles matched to coil weight
  • Individual mill / coil identification on packing records
  • Container and unloading restrictions communicated before shipping
ENGINEERING QUESTIONS / PURCHASING ANSWERS

50W470 Electrical Steel Coil FAQ

These answers support preliminary material selection and RFQ preparation; actual test results are tied to the contracted supplying mill and lot.

What does the 50W470 electrical steel designation mean?

The designation denotes a nominal 0.50 mm non-oriented electrical steel loss class associated with a P1.5/50 ceiling of 4.70 W/kg. The mill-issued datasheet and contract determine the actual acceptance criteria.

Is 4.70 W/kg guaranteed on every 50W470 coil?

4.70 W/kg at 1.5 T and 50 Hz is the grade-class target. A particular shipment is accepted against the supplying mill’s contracted grade, specified test method and certified P1.5/50 result.

Which standards can be used for 50W470?

GB/T 2521.1-2016 is the current Chinese specification for fully processed non-oriented electrical strip. IEC 60404-8-4:2022 with Amendment 1:2026 is an international reference. Use the agreed standard edition and grade mapping in the purchase contract.

Is 50W470 equivalent to B50A470 or M470-50A?

They belong to comparable 0.50 mm / 4.70 W/kg loss classes in published product literature. Grade conversion is subject to induction, coating, thickness tolerance, inspection method, mill data and customer qualification.

What is the B50 requirement for 50W470?

B50/J5000 is evaluated at a magnetic field strength of 5,000 A/m. A published B50A470 mill reference lists 1.64 T minimum; request a guaranteed value and actual result for the 50W470 lot you are buying.

How is 50W470 different from 35W470?

The nominal metal thickness is 0.50 mm instead of 0.35 mm. This changes coil length at the same mass, lamination count, punching setup and potentially eddy-current loss. Compare full magnetic datasets before switching.

Is 50W470 suitable for industrial motors and compressors?

It is commonly evaluated for motor laminations and compressor or fan motors. A design-specific performance review should cover operating frequency, core geometry, efficiency requirements, insulation and measured magnetic loss.

What insulation coatings are available?

Available coating grades are mill- and order-dependent. Specify the coating system, interlaminar resistance, thickness, post-punch processing and bonding or welding needs in your RFQ.

Can 50W470 be delivered as narrow slit coils?

Slitting can be quoted subject to actual available parent-coil width, minimum slit width, burr tolerance, coating integrity and coil-pack requirements. Send the stamped-part drawing for a reliable estimate.

How can I estimate 50W470 coil length?

For a simplified estimate: meters = net coil mass (kg) ÷ [base thickness (mm) × width (mm) × density (g/cm³) × 0.001]. Use the confirmed material density and account separately for insulation coating and cutting scrap.

Which inspection documents should accompany electrical steel coils?

Request the mill grade specification, traceable MTC, P1.5/50 and B50 results under the agreed test methods, coating record, gauge/width data and the applicable packing list.

What details are needed for a bulk 50W470 quotation?

Send the grade and supply standard, 0.50 mm gauge, finished/slit width, individual coil ID and mass, total tonnage, core loss and induction requirements, coating, inspection terms, delivery destination and any trial-sample requirements.

BAOSTEEL METAL / ELECTRICAL STEEL COIL

Request 50W470 Non-Oriented Electrical Steel Coil Pricing

Send the supplying mill designation, certified P1.5/50 and B50 requirements, 0.50 mm nominal gauge, slit width, insulation type, coil mass and annual or project tonnage. Add your stamping drawing, delivery destination and trial-approval plan.

WhatsAppEmail Us
Include in your electrical-steel RFQ
  • 50W470 designation and actual mill specification
  • Nominal thickness, width, coil ID and weight
  • P1.5/50 and B50/J5000 acceptance limits
  • Insulating coating, slitting and edge tolerance
  • Order quantity, magnetic MTC and destination

Email: [email protected]